PRODUCT
Fluid-bed Processor
Product Details:
Model:
Certification:
CE, cGMP, ISO9001:2010
Delivery Time:
60~90 days upon down payment and technical clarification
Payment Terms:
T/T, L/C

FBP Fluid-bed Processor is mainly used for fluid-bed processing in the pharmaceutical solid dosage production.
The system includes AHU, material bowl and processing chambers, exhaust air filtering units and control parts. Additionally, the system includes exchangeable bowls for other functions. 


Top spray granulation
Filtered hot air blows up materials to fluidized state. A spray nozzle on the top sprays atomized binder solution and powders agglomerate in the fluidized flow. In this process, granulation and drying is finished in single processor, so it is also called one-step granulation. 
Top spray produced granules are of excellent solubility and low bulk density. 


Bottom spray coating
The key of bottom spray coating is material flow control. The bottom air distribution plate is dedicated to accomulate materials at the bottom and blow up from the internal of cylinders, building a steady and continuous free flowing of materials. The cylinder height is adjustable to match up processing air pressure. 
FBP Fluid-bed Processor is the most common form of drying machine used in pharmaceutical production. It is also widely used in food, chemical industries.

Filter leakage detect
On-line sampling
End-point process control
Repeatability and traceability
  
Options
Vacuum charging/discharging
Explosion-proof @ 2 bar
Explosion-proof @ 10 bar
Process air dehumidification
SCHLICK spray nozzle
Process air pre-heating
WIP setup
CFR 21 Part 11 compliant data collection system


Model FBP5 FBP10 FBP30 FBP60 FBP120 FBP200 FBP300

Bowl Volume

[L]

Top Spray 29 37 112 221 453 675 1018
Bottom Spray 32.5 32.5 90 131 405 463 885
Tangential Spray 19 19 54 75 217 - -

Max Capacity

[Kg/batch]

Top Spray 5 10 30 60 120 200 300
Bottom Spray 4 10 20 35 80 150 300
Tangential Spray 2 5 15 25 60 - -
Steam Pressure [MPa] 0.4~0.6
Steam Consumption [kg/h] 80 80 166 166 420 480 790
Compressed Air Pressure [MPa] 0.4~0.7

Compressed Air Consumption

[m³/min]

2.1 2.1 2.5 2.7 3 3.5 3.8
Hot Air Regulating Range [°C] Room temperature ~ 120
Intake Air Filtering Primary filter G4, medium filter F8, HEPA filter H13
Air Fan Power [kW] 7.5 11 11 18.5 30 30 45
Dimensions [mm]

1200x800

x3720

1200x800

x3720

1480x1000

x4100

1690x1200

x4730

1880x1400

x5180

2088x1600

x5480

2290x1800

x5850

Machine

Weight

[kg]

Main Machine 2200 2200 2500 3000 4000 5000 6000
AHU 1100 1100 1300 1300 1400 1500 1600
Dust Collector 700 700 800 800 900 900 1000
Air Fan 550 550 650 650 750 800 850